Weight | 250 g (including integrated amplifier) |
Autonomy | > 3 hours per battery |
Bandwidth | 0 Hz (DC) – 40 Hz (3rd order low-pass filter) |
Data Backup | MicroSD card (up to 8 GB, class = 10), CSV format |
Sensor Type | Dry-EEG sensors, active shielding, optimised DRL |
Power Supply | Swappable rechargeable LiPo, 700mAh (<3h charge) |
Product Type | Wearable dry-EEG headset |
Additional Inputs | 1 x digital (1 bit), 1 x optical trigger |
Data Transmission | Bluetooth 2.1 + EDR (range: 10 m direct) |
Integrated Sensors | 9-axis IMU (accelerometer, gyroscope, magnetometer) |
Number of Channels | 9 x EEG (FC3, FCz, FC4, C3, Cz, C4, CP3, CPz, CP4), Linked ear reference (A2), REF (A1), DRL (A1) |
Input Range & Noise | ± 100 mV, < 1 µVRMS (0.5–30 Hz) @256 Hz |
CMRR / Input Impedance | > 100 dB @50 Hz / > 50 GO |
Software Compatibility | Includes Bitbrain Software Kit (C/C++ SDK); supports LSL for real-time I/O with third-party software (e.g., BCI2000, OpenVibe, NeuroPype, MATLAB, EEGLAB, Python MNE) |
Head Breadth Compatibility | 13.5 cm - 16.5 cm |
Sampling Rate / Resolution | 256 SPS @ 24 bit |
Bitbrain is an industry-leading neurotechnology company, integrating neuroscience, AI, and hardware to deliver EEG brain-sensing devices and software solutions for applied research and healthcare.
To contact Aerobe about EEG System | Hero EEG (9ch) use Get a quote.
Weight | 250 g (including integrated amplifier) |
Autonomy | > 3 hours per battery |
Bandwidth | 0 Hz (DC) – 40 Hz (3rd order low-pass filter) |
Data Backup | MicroSD card (up to 8 GB, class = 10), CSV format |
Sensor Type | Dry-EEG sensors, active shielding, optimised DRL |
Power Supply | Swappable rechargeable LiPo, 700mAh (<3h charge) |
Product Type | Wearable dry-EEG headset |
Additional Inputs | 1 x digital (1 bit), 1 x optical trigger |
Data Transmission | Bluetooth 2.1 + EDR (range: 10 m direct) |
Integrated Sensors | 9-axis IMU (accelerometer, gyroscope, magnetometer) |
Number of Channels | 9 x EEG (FC3, FCz, FC4, C3, Cz, C4, CP3, CPz, CP4), Linked ear reference (A2), REF (A1), DRL (A1) |
Input Range & Noise | ± 100 mV, < 1 µVRMS (0.5–30 Hz) @256 Hz |
CMRR / Input Impedance | > 100 dB @50 Hz / > 50 GO |
Software Compatibility | Includes Bitbrain Software Kit (C/C++ SDK); supports LSL for real-time I/O with third-party software (e.g., BCI2000, OpenVibe, NeuroPype, MATLAB, EEGLAB, Python MNE) |
Head Breadth Compatibility | 13.5 cm - 16.5 cm |
Sampling Rate / Resolution | 256 SPS @ 24 bit |