BioSan UV workstation for decontamination ...
Key Features
Product Description
The UVC/T-M-AR UV workstation has been designed to decontaminate reagents and equipment of nucleic acids prior to PCR set up. An open UV lamp emitting at 254 nm denatures nucleic acids in 15-30 minutes making them unsuitable for amplification and therefore eliminating the possibility of cross-contamination during the PCR process.
For additional denaturing/ cleaning power the workstation includes a bactericidal air cleaner-recirculator enclosure with UV lamp, fans and inlet and outlet filters that provides constant decontamination inside the cabinet during operation. The cabinet is also equipped with a white lamp for illumination.
The lower part of the cabinet front panel lifts up to provide access to the interior and a UV safety interlock turns off the UV light when the panel is opened. There is one built-in power socket and a port in the back wall of the unit that allows cables from additional centrifuges, vortexers, etc. to be plugged into external sockets.
The front and side glass panels are coated with a protective film that blocks >96% of UV emissions. The workstation stands on an easy to clean stainless steel tray.
Specifications
Manufacturer | BioSan |
Model number | UVC/T-M-AR |
Construction | Back panel: stainless steel | side and front panels: glass | working surface : stainless steel |
Open UV lamp | 1 ? TUV 25 W G13 UV-C |
Cleaner-recirculator UV lamp | 1 ? TUV 25 W G13 UV-C |
White light lamp | 1 ? TLD 15 W G-13 |
UV radiation level | 15 mW/cm²/second |
Radiation type | 253.7 UV: ozone-free |
Timer range for direct UV exposure (open lamp) | 1 minute to 24 hours in 1 minute increments or continuous |
Panel thickness | Side panels: 4 mm | upper front panel: 8 mm | protective screen: 4 mm |
Optical transmission | 95% |
UV blocking | 96% |
Internal sockets for power cords | 1: up to maximum of 1000 W |
Working area | 645 mm x 490 mm |
Opening dimensions (protective screen fully raised) | 645 mm x 190 mm |
Overall dimensions (W x D x H) | 700 mm x 580 mm x 555 mm |
Weight | 39 Kg |
Power consumption | 67 W |
Power requirements | 100 - 240 VAC; 50/60 Hz |
To contact Advance Scientific Products Pty Ltd about BioSan UV workstation for decontamination and PCR set-up | L020-GC use Get a quote.
Key Features
Product Description
The UVC/T-M-AR UV workstation has been designed to decontaminate reagents and equipment of nucleic acids prior to PCR set up. An open UV lamp emitting at 254 nm denatures nucleic acids in 15-30 minutes making them unsuitable for amplification and therefore eliminating the possibility of cross-contamination during the PCR process.
For additional denaturing/ cleaning power the workstation includes a bactericidal air cleaner-recirculator enclosure with UV lamp, fans and inlet and outlet filters that provides constant decontamination inside the cabinet during operation. The cabinet is also equipped with a white lamp for illumination.
The lower part of the cabinet front panel lifts up to provide access to the interior and a UV safety interlock turns off the UV light when the panel is opened. There is one built-in power socket and a port in the back wall of the unit that allows cables from additional centrifuges, vortexers, etc. to be plugged into external sockets.
The front and side glass panels are coated with a protective film that blocks >96% of UV emissions. The workstation stands on an easy to clean stainless steel tray.
Specifications
Manufacturer | BioSan |
Model number | UVC/T-M-AR |
Construction | Back panel: stainless steel | side and front panels: glass | working surface : stainless steel |
Open UV lamp | 1 ? TUV 25 W G13 UV-C |
Cleaner-recirculator UV lamp | 1 ? TUV 25 W G13 UV-C |
White light lamp | 1 ? TLD 15 W G-13 |
UV radiation level | 15 mW/cm²/second |
Radiation type | 253.7 UV: ozone-free |
Timer range for direct UV exposure (open lamp) | 1 minute to 24 hours in 1 minute increments or continuous |
Panel thickness | Side panels: 4 mm | upper front panel: 8 mm | protective screen: 4 mm |
Optical transmission | 95% |
UV blocking | 96% |
Internal sockets for power cords | 1: up to maximum of 1000 W |
Working area | 645 mm x 490 mm |
Opening dimensions (protective screen fully raised) | 645 mm x 190 mm |
Overall dimensions (W x D x H) | 700 mm x 580 mm x 555 mm |
Weight | 39 Kg |
Power consumption | 67 W |
Power requirements | 100 - 240 VAC; 50/60 Hz |
To contact Advance Scientific Products Pty Ltd about BioSan UV workstation for decontamination and PCR set-up | L020-GC use Get a quote.
Thanks for your help!