The PM6800VCS is a multi-parameter veterinary monitor with 15.1 inches high resolution LCD display. It is intended to be used in veterinary clinics and hospitals to measure animals’ SpO2, Pulse rate, Non-invasive blood pressure, Temperature, 5-lead/3-lead electrocardiography (ECG) and Respiration rate, capnography (ETCO2). It Invasive blood pressure (IBP) is an optional parameters.
Main Features:
Main unit: 2 years
Accessories: 6 months
Technical Specification | ||||||||
Enclosure | ||||||||
Weight | 8 kg(17.6 lbs) | |||||||
Dimensions |
|
|||||||
Display | 15-inch diagonal high-resolution TFT (Thin Film Transistor) Active Matrix LCD | |||||||
Alarms | ||||||||
Categories | Patient status and system status | |||||||
Notification | Audible and visual | |||||||
Setting | Full storage, low battery and sensor off | |||||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%), NIBP (0-300mmHg), RESP (5-150rpm), TEMP (24.5-45.5?) | |||||||
Alarm volume level | 45dBA to 85 dBA at 1 meter distance (adjustable) | |||||||
Range, Accuracy and Resolution | ||||||||
Range Type | Range Values | |||||||
Measurement Ranges | ||||||||
SpO2 | 0-100% | |||||||
Pulse rate | 30-350bpm | |||||||
NIBP | Systolic:40 to 270 mmHg Mean Arterial:30 to 220 mmHg Diastolic:20 to 200 mmHg |
|||||||
RESP | 0-150rpm | |||||||
TEMP | 0-50? | |||||||
Measurement Accuracy | ||||||||
SpO2 | 70-100% (±2%), <70% undefined | |||||||
Pulse rate | ±2bpm/±2% take maximum | |||||||
ETCO2 | 0~40mmHg ±2mmHg, 41~150mmHg ±10% | |||||||
TEMP | ±0.2? | |||||||
RESP | ±1rpm | |||||||
Resolution | ||||||||
Display | 800 X 600 pixels | |||||||
SpO2 | 1% | |||||||
ETCO2 | 0.1mmHg | |||||||
TEMP | 0.1? | |||||||
RESP | 1rpm | |||||||
Pulse rate | 1bpm | |||||||
Electrical | ||||||||
AC power requirement | 100-240VA, 50/60Hz | |||||||
Batteries | ||||||||
Types | Lithium-lon Batteries | |||||||
Operating time | =4hours | |||||||
Charge time | =4hours | |||||||
Environment | ||||||||
Operating tempearture | 0-50? | |||||||
Storage temperature | -40-75? | |||||||
Operating humidity | 15-95% | |||||||
Storage humidity | 10-95% | |||||||
Operating altitude | -500-5000m | |||||||
Standards and Certification | ||||||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | |||||||
IEC 62304 | Medical device-software life cycle processes | |||||||
MDD 93/42/EEC | European Medical Device Directive | |||||||
ISO 13485 | Medical equipment-Quality management system | |||||||
EN ISO 14971 | Medical devices-Risk management | |||||||
EN 60601-1 | Medical electrical equipment | |||||||
EN 60601-2 | Medical electrical equipment | |||||||
EN 60601-8 | Medical electrical equipment | |||||||
EN 980 | Symbols for use in labeling of medical devices | |||||||
EN 1041 | Information supplied by the manufacture of medical devices | |||||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | |||||||
EN ISO 10993-1 | Biological evaluation of medical devices | |||||||
EN ISO 10993-5 | Biological evaluation of medical devices | |||||||
EN ISO 10993-10 | Biological evaluation of medical devices | |||||||
ISO 14155-1 | Clinical investigation of medical devices | |||||||
CE | CONFORMITE EUROPEENNE | |||||||
SFDA | State Food and Drug Administration |
To contact Utech Medical Device Pty Ltd about UTMD PM6800VCS 15" Veterinary Patient Monitor - ECG SPO2 NIBP TEMP ETCO2 use Get a quote.
The PM6800VCS is a multi-parameter veterinary monitor with 15.1 inches high resolution LCD display. It is intended to be used in veterinary clinics and hospitals to measure animals’ SpO2, Pulse rate, Non-invasive blood pressure, Temperature, 5-lead/3-lead electrocardiography (ECG) and Respiration rate, capnography (ETCO2). It Invasive blood pressure (IBP) is an optional parameters.
Main Features:
Main unit: 2 years
Accessories: 6 months
Technical Specification | ||||||||
Enclosure | ||||||||
Weight | 8 kg(17.6 lbs) | |||||||
Dimensions |
|
|||||||
Display | 15-inch diagonal high-resolution TFT (Thin Film Transistor) Active Matrix LCD | |||||||
Alarms | ||||||||
Categories | Patient status and system status | |||||||
Notification | Audible and visual | |||||||
Setting | Full storage, low battery and sensor off | |||||||
Range | Pulse rate (30-350bpm), SpO2 (0-100%), NIBP (0-300mmHg), RESP (5-150rpm), TEMP (24.5-45.5?) | |||||||
Alarm volume level | 45dBA to 85 dBA at 1 meter distance (adjustable) | |||||||
Range, Accuracy and Resolution | ||||||||
Range Type | Range Values | |||||||
Measurement Ranges | ||||||||
SpO2 | 0-100% | |||||||
Pulse rate | 30-350bpm | |||||||
NIBP | Systolic:40 to 270 mmHg Mean Arterial:30 to 220 mmHg Diastolic:20 to 200 mmHg |
|||||||
RESP | 0-150rpm | |||||||
TEMP | 0-50? | |||||||
Measurement Accuracy | ||||||||
SpO2 | 70-100% (±2%), <70% undefined | |||||||
Pulse rate | ±2bpm/±2% take maximum | |||||||
ETCO2 | 0~40mmHg ±2mmHg, 41~150mmHg ±10% | |||||||
TEMP | ±0.2? | |||||||
RESP | ±1rpm | |||||||
Resolution | ||||||||
Display | 800 X 600 pixels | |||||||
SpO2 | 1% | |||||||
ETCO2 | 0.1mmHg | |||||||
TEMP | 0.1? | |||||||
RESP | 1rpm | |||||||
Pulse rate | 1bpm | |||||||
Electrical | ||||||||
AC power requirement | 100-240VA, 50/60Hz | |||||||
Batteries | ||||||||
Types | Lithium-lon Batteries | |||||||
Operating time | =4hours | |||||||
Charge time | =4hours | |||||||
Environment | ||||||||
Operating tempearture | 0-50? | |||||||
Storage temperature | -40-75? | |||||||
Operating humidity | 15-95% | |||||||
Storage humidity | 10-95% | |||||||
Operating altitude | -500-5000m | |||||||
Standards and Certification | ||||||||
IEC 62366 | Medical devices-Application of usability engineering to medical devices | |||||||
IEC 62304 | Medical device-software life cycle processes | |||||||
MDD 93/42/EEC | European Medical Device Directive | |||||||
ISO 13485 | Medical equipment-Quality management system | |||||||
EN ISO 14971 | Medical devices-Risk management | |||||||
EN 60601-1 | Medical electrical equipment | |||||||
EN 60601-2 | Medical electrical equipment | |||||||
EN 60601-8 | Medical electrical equipment | |||||||
EN 980 | Symbols for use in labeling of medical devices | |||||||
EN 1041 | Information supplied by the manufacture of medical devices | |||||||
ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | |||||||
EN ISO 10993-1 | Biological evaluation of medical devices | |||||||
EN ISO 10993-5 | Biological evaluation of medical devices | |||||||
EN ISO 10993-10 | Biological evaluation of medical devices | |||||||
ISO 14155-1 | Clinical investigation of medical devices | |||||||
CE | CONFORMITE EUROPEENNE | |||||||
SFDA | State Food and Drug Administration |