UTMD PM6800VCS 15" Veterinary Patient ...
The PM6800VCS is a multi-parameter veterinary monitor with 15.1 inches high resolution LCD display. It is intended to be used in veterinary clinics and hospitals to measure animals’ SpO2, Pulse rate, Non-invasive blood pressure, Temperature, 5-lead/3-lead electrocardiography (ECG) and Respiration rate, capnography (ETCO2). It Invasive blood pressure (IBP) is an optional parameters.
Main Features:
Main unit: 2 years
Accessories: 6 months
| Technical Specification | ||||||||
| Enclosure | ||||||||
| Weight | 8 kg(17.6 lbs) | |||||||
| Dimensions |
|
|||||||
| Display | 15-inch diagonal high-resolution TFT (Thin Film Transistor) Active Matrix LCD | |||||||
| Alarms | ||||||||
| Categories | Patient status and system status | |||||||
| Notification | Audible and visual | |||||||
| Setting | Full storage, low battery and sensor off | |||||||
| Range | Pulse rate (30-350bpm), SpO2 (0-100%), NIBP (0-300mmHg), RESP (5-150rpm), TEMP (24.5-45.5?) | |||||||
| Alarm volume level | 45dBA to 85 dBA at 1 meter distance (adjustable) | |||||||
| Range, Accuracy and Resolution | ||||||||
| Range Type | Range Values | |||||||
| Measurement Ranges | ||||||||
| SpO2 | 0-100% | |||||||
| Pulse rate | 30-350bpm | |||||||
| NIBP | Systolic:40 to 270 mmHg Mean Arterial:30 to 220 mmHg Diastolic:20 to 200 mmHg |
|||||||
| RESP | 0-150rpm | |||||||
| TEMP | 0-50? | |||||||
| Measurement Accuracy | ||||||||
| SpO2 | 70-100% (±2%), <70% undefined | |||||||
| Pulse rate | ±2bpm/±2% take maximum | |||||||
| ETCO2 | 0~40mmHg ±2mmHg, 41~150mmHg ±10% | |||||||
| TEMP | ±0.2? | |||||||
| RESP | ±1rpm | |||||||
| Resolution | ||||||||
| Display | 800 X 600 pixels | |||||||
| SpO2 | 1% | |||||||
| ETCO2 | 0.1mmHg | |||||||
| TEMP | 0.1? | |||||||
| RESP | 1rpm | |||||||
| Pulse rate | 1bpm | |||||||
| Electrical | ||||||||
| AC power requirement | 100-240VA, 50/60Hz | |||||||
| Batteries | ||||||||
| Types | Lithium-lon Batteries | |||||||
| Operating time | =4hours | |||||||
| Charge time | =4hours | |||||||
| Environment | ||||||||
| Operating tempearture | 0-50? | |||||||
| Storage temperature | -40-75? | |||||||
| Operating humidity | 15-95% | |||||||
| Storage humidity | 10-95% | |||||||
| Operating altitude | -500-5000m | |||||||
| Standards and Certification | ||||||||
| IEC 62366 | Medical devices-Application of usability engineering to medical devices | |||||||
| IEC 62304 | Medical device-software life cycle processes | |||||||
| MDD 93/42/EEC | European Medical Device Directive | |||||||
| ISO 13485 | Medical equipment-Quality management system | |||||||
| EN ISO 14971 | Medical devices-Risk management | |||||||
| EN 60601-1 | Medical electrical equipment | |||||||
| EN 60601-2 | Medical electrical equipment | |||||||
| EN 60601-8 | Medical electrical equipment | |||||||
| EN 980 | Symbols for use in labeling of medical devices | |||||||
| EN 1041 | Information supplied by the manufacture of medical devices | |||||||
| ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | |||||||
| EN ISO 10993-1 | Biological evaluation of medical devices | |||||||
| EN ISO 10993-5 | Biological evaluation of medical devices | |||||||
| EN ISO 10993-10 | Biological evaluation of medical devices | |||||||
| ISO 14155-1 | Clinical investigation of medical devices | |||||||
| CE | CONFORMITE EUROPEENNE | |||||||
| SFDA | State Food and Drug Administration | |||||||
To contact Utech Medical Device Pty Ltd about UTMD PM6800VCS 15" Veterinary Patient Monitor - ECG SPO2 NIBP TEMP ETCO2 use Get a quote.
The PM6800VCS is a multi-parameter veterinary monitor with 15.1 inches high resolution LCD display. It is intended to be used in veterinary clinics and hospitals to measure animals’ SpO2, Pulse rate, Non-invasive blood pressure, Temperature, 5-lead/3-lead electrocardiography (ECG) and Respiration rate, capnography (ETCO2). It Invasive blood pressure (IBP) is an optional parameters.
Main Features:
Main unit: 2 years
Accessories: 6 months
| Technical Specification | ||||||||
| Enclosure | ||||||||
| Weight | 8 kg(17.6 lbs) | |||||||
| Dimensions |
|
|||||||
| Display | 15-inch diagonal high-resolution TFT (Thin Film Transistor) Active Matrix LCD | |||||||
| Alarms | ||||||||
| Categories | Patient status and system status | |||||||
| Notification | Audible and visual | |||||||
| Setting | Full storage, low battery and sensor off | |||||||
| Range | Pulse rate (30-350bpm), SpO2 (0-100%), NIBP (0-300mmHg), RESP (5-150rpm), TEMP (24.5-45.5?) | |||||||
| Alarm volume level | 45dBA to 85 dBA at 1 meter distance (adjustable) | |||||||
| Range, Accuracy and Resolution | ||||||||
| Range Type | Range Values | |||||||
| Measurement Ranges | ||||||||
| SpO2 | 0-100% | |||||||
| Pulse rate | 30-350bpm | |||||||
| NIBP | Systolic:40 to 270 mmHg Mean Arterial:30 to 220 mmHg Diastolic:20 to 200 mmHg |
|||||||
| RESP | 0-150rpm | |||||||
| TEMP | 0-50? | |||||||
| Measurement Accuracy | ||||||||
| SpO2 | 70-100% (±2%), <70% undefined | |||||||
| Pulse rate | ±2bpm/±2% take maximum | |||||||
| ETCO2 | 0~40mmHg ±2mmHg, 41~150mmHg ±10% | |||||||
| TEMP | ±0.2? | |||||||
| RESP | ±1rpm | |||||||
| Resolution | ||||||||
| Display | 800 X 600 pixels | |||||||
| SpO2 | 1% | |||||||
| ETCO2 | 0.1mmHg | |||||||
| TEMP | 0.1? | |||||||
| RESP | 1rpm | |||||||
| Pulse rate | 1bpm | |||||||
| Electrical | ||||||||
| AC power requirement | 100-240VA, 50/60Hz | |||||||
| Batteries | ||||||||
| Types | Lithium-lon Batteries | |||||||
| Operating time | =4hours | |||||||
| Charge time | =4hours | |||||||
| Environment | ||||||||
| Operating tempearture | 0-50? | |||||||
| Storage temperature | -40-75? | |||||||
| Operating humidity | 15-95% | |||||||
| Storage humidity | 10-95% | |||||||
| Operating altitude | -500-5000m | |||||||
| Standards and Certification | ||||||||
| IEC 62366 | Medical devices-Application of usability engineering to medical devices | |||||||
| IEC 62304 | Medical device-software life cycle processes | |||||||
| MDD 93/42/EEC | European Medical Device Directive | |||||||
| ISO 13485 | Medical equipment-Quality management system | |||||||
| EN ISO 14971 | Medical devices-Risk management | |||||||
| EN 60601-1 | Medical electrical equipment | |||||||
| EN 60601-2 | Medical electrical equipment | |||||||
| EN 60601-8 | Medical electrical equipment | |||||||
| EN 980 | Symbols for use in labeling of medical devices | |||||||
| EN 1041 | Information supplied by the manufacture of medical devices | |||||||
| ISO 80601-2-61 | Medical electrical equipment-Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use | |||||||
| EN ISO 10993-1 | Biological evaluation of medical devices | |||||||
| EN ISO 10993-5 | Biological evaluation of medical devices | |||||||
| EN ISO 10993-10 | Biological evaluation of medical devices | |||||||
| ISO 14155-1 | Clinical investigation of medical devices | |||||||
| CE | CONFORMITE EUROPEENNE | |||||||
| SFDA | State Food and Drug Administration | |||||||
To contact Utech Medical Device Pty Ltd about UTMD PM6800VCS 15" Veterinary Patient Monitor - ECG SPO2 NIBP TEMP ETCO2 use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.