LogTag WHO Prequalified Vaccine Data Logger ...
It is specifically configured and packaged to be compliant to the World Health Organisation (WHO) PQS specification E006/TR06.3.
Key Features
Specifications
| Product Model | TRID30-7FW. |
| Sensor Measurement Range | -30°C to +60°C (-22°F to +140°F). |
| Operating Temperature Range | -30°C to +60°C (-22°F to +140°F). |
| Storage Temperature Range | -10°C to +40°C (14°F to +104°F). |
| Rated Temperature Reading Accuracy | Better than ±0.5°C for -20°C to +40°C typically ±0.3°C. Better than ±0.8°C for other measurements typically ±0.5°C. Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below. Accuracy figures can be improved by recalibration. |
| Rated Temperature Reading Resolution | 0.1°C for measurements -30°C to +40°C. 0.2°C for measurements above +40°C. Please see the Rated Native Resolution chart below. LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
| Sensor Reaction Time | Typically less than 5 minutes (T90) in moving air (1m/s). |
| Recording Capacity | 7770 temperature readings. 32 days @ 6 minute logging. |
| Sampling Interval | Factory set to 6 minute interval. |
| Logging Start Options | Factory set to Push button start. |
| Recording Indication | State indicator “RECORDING”. |
| Alarm Triggering | Low alarm : Exposure to a single temperature event of -0.5°C or below for 60 minutes. High alarm: Exposure to a single temperature event of +8°C or above for 10 hours. |
| Download Time | Typically less than 5 seconds for full memory (7770 readings), depending on computer or readout device used. |
| Environmental | IP65 (roughly equivalent to NEMA 4) when vertically mounted or hung. |
| Power Source | 3V Lithium-Manganese Dioxide extended temperature chemistry. |
| Battery Life | Typically 2+ years of operation. This assumes day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time. |
| Real Time Clock | Built-in real time clock. Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C). |
| Size | 90mm(H) x 54.5mm(W) x 8.6mm(T). |
| Weight | 43g. |
| Case Material | Polycarbonate. |
To contact Global Cold Chain Solutions about LogTag WHO Prequalified Vaccine Data Logger | Vaxtag® use Get a quote.
It is specifically configured and packaged to be compliant to the World Health Organisation (WHO) PQS specification E006/TR06.3.
Key Features
Specifications
| Product Model | TRID30-7FW. |
| Sensor Measurement Range | -30°C to +60°C (-22°F to +140°F). |
| Operating Temperature Range | -30°C to +60°C (-22°F to +140°F). |
| Storage Temperature Range | -10°C to +40°C (14°F to +104°F). |
| Rated Temperature Reading Accuracy | Better than ±0.5°C for -20°C to +40°C typically ±0.3°C. Better than ±0.8°C for other measurements typically ±0.5°C. Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below. Accuracy figures can be improved by recalibration. |
| Rated Temperature Reading Resolution | 0.1°C for measurements -30°C to +40°C. 0.2°C for measurements above +40°C. Please see the Rated Native Resolution chart below. LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®. |
| Sensor Reaction Time | Typically less than 5 minutes (T90) in moving air (1m/s). |
| Recording Capacity | 7770 temperature readings. 32 days @ 6 minute logging. |
| Sampling Interval | Factory set to 6 minute interval. |
| Logging Start Options | Factory set to Push button start. |
| Recording Indication | State indicator “RECORDING”. |
| Alarm Triggering | Low alarm : Exposure to a single temperature event of -0.5°C or below for 60 minutes. High alarm: Exposure to a single temperature event of +8°C or above for 10 hours. |
| Download Time | Typically less than 5 seconds for full memory (7770 readings), depending on computer or readout device used. |
| Environmental | IP65 (roughly equivalent to NEMA 4) when vertically mounted or hung. |
| Power Source | 3V Lithium-Manganese Dioxide extended temperature chemistry. |
| Battery Life | Typically 2+ years of operation. This assumes day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time. |
| Real Time Clock | Built-in real time clock. Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C). |
| Size | 90mm(H) x 54.5mm(W) x 8.6mm(T). |
| Weight | 43g. |
| Case Material | Polycarbonate. |
To contact Global Cold Chain Solutions about LogTag WHO Prequalified Vaccine Data Logger | Vaxtag® use Get a quote.