CSO Anterior Segment OCT | MS-39 | Corneal ...
The most advanced device for the analysis of the anterior segment of the eye. MS-39 combines Placido disk corneal topography, with high resolution OCT-based anterior segment tomography. The clarity of the cross-sectional images, with a 16 mm diameter, along with the many details of the cornea structure and layers revealed by the MS-39, will be appreciated by anterior segment specialists. MS-39 provides information on pachymetry, elevation, curvature and dioptric power of both corneal sufaces.
In addition to anterior segment clinical diagnostics, MS-39 can be used in corneal surgery for refractive surgery planning. An IOL calculation module is also available, based on Ray-Tracing techniques, Additional tools allow MS-39 to perform accurate pupil diameter measuremets and the advanced analysis of tear film.
CORNEAL SECTION
EPITHELIAL AND STROMAL MAP
CORNEAL ABERROMETRY
KERATOCONOUS SCREENING
CRYSTALLINE BIOMETRY
TECHNICAL DATA
Data transfer | USB 3.0 |
Power supply | external power source 24 VDC In: 100-240Vac - 50/60Hz - 2A - Out: 24Vdc - 100W |
Power cable | IEC C14 plug |
Dimensions (HxWxD | 505 x 315 x 251mm |
Weight | 10.4Kg |
Chin rest movement | 70mm ± 1mm |
Minimum height of the chin cup from table | 23cm |
Base movement (xyz) | 105 x 110 x 30mm |
Working distance: | 74mm |
LIGHT SOURCES | |
Placido disk illumination | Led @635nm |
OCT source | SLed @845nm |
Pupillographic illumination | Led @950nm |
TOPOGRAPHY | |
Placido disk rings | 22 |
Measured points | 31232 (anterior surface) 25600 (posterior surface) |
Topographic covering | 10mm |
Dioptric measurement range | from 1D to 100D |
Measurement accuracy | Class A according to UNI EN ISO 19980-2012 |
TOMOGRAPHIC SECTION | |
Image field | 16mm x 8mm |
Axial resolution | >3.6µm (in tissue) |
Transversal resolution | 35µm (in air) |
Image(s) resolution | Keratoscopy (640x480) + 25 radial scans on a 16mm transversal field (1024 A-scan) - Section: on 16mm (1600 A-scan) on 8mm (800 A-scan) |
MINIMUM SYSTEM REQUIREMENT | |
PC: 4 GB RAM - Scheda Video 1 GB RAM (non condivisa) risoluzione 1024 x 768 pixels - USB 3.0 type A Sistema operati vo: Windows XP, Windows 7 e Windows 10 (32/64 bit). |
To contact Eyetek about CSO Anterior Segment OCT | MS-39 | Corneal Topography & Tomography use Get a quote.
The most advanced device for the analysis of the anterior segment of the eye. MS-39 combines Placido disk corneal topography, with high resolution OCT-based anterior segment tomography. The clarity of the cross-sectional images, with a 16 mm diameter, along with the many details of the cornea structure and layers revealed by the MS-39, will be appreciated by anterior segment specialists. MS-39 provides information on pachymetry, elevation, curvature and dioptric power of both corneal sufaces.
In addition to anterior segment clinical diagnostics, MS-39 can be used in corneal surgery for refractive surgery planning. An IOL calculation module is also available, based on Ray-Tracing techniques, Additional tools allow MS-39 to perform accurate pupil diameter measuremets and the advanced analysis of tear film.
CORNEAL SECTION
EPITHELIAL AND STROMAL MAP
CORNEAL ABERROMETRY
KERATOCONOUS SCREENING
CRYSTALLINE BIOMETRY
TECHNICAL DATA
Data transfer | USB 3.0 |
Power supply | external power source 24 VDC In: 100-240Vac - 50/60Hz - 2A - Out: 24Vdc - 100W |
Power cable | IEC C14 plug |
Dimensions (HxWxD | 505 x 315 x 251mm |
Weight | 10.4Kg |
Chin rest movement | 70mm ± 1mm |
Minimum height of the chin cup from table | 23cm |
Base movement (xyz) | 105 x 110 x 30mm |
Working distance: | 74mm |
LIGHT SOURCES | |
Placido disk illumination | Led @635nm |
OCT source | SLed @845nm |
Pupillographic illumination | Led @950nm |
TOPOGRAPHY | |
Placido disk rings | 22 |
Measured points | 31232 (anterior surface) 25600 (posterior surface) |
Topographic covering | 10mm |
Dioptric measurement range | from 1D to 100D |
Measurement accuracy | Class A according to UNI EN ISO 19980-2012 |
TOMOGRAPHIC SECTION | |
Image field | 16mm x 8mm |
Axial resolution | >3.6µm (in tissue) |
Transversal resolution | 35µm (in air) |
Image(s) resolution | Keratoscopy (640x480) + 25 radial scans on a 16mm transversal field (1024 A-scan) - Section: on 16mm (1600 A-scan) on 8mm (800 A-scan) |
MINIMUM SYSTEM REQUIREMENT | |
PC: 4 GB RAM - Scheda Video 1 GB RAM (non condivisa) risoluzione 1024 x 768 pixels - USB 3.0 type A Sistema operati vo: Windows XP, Windows 7 e Windows 10 (32/64 bit). |