Technical Specification:
| Fit IV Tubes | Can be used with any brand IV set after exactly calibration |
| Infusion Mode | Volumetric |
| Pumping Mechanism | Peristaltic finger pump |
| IV Sets | Standard IV sets of 10, 15, 20 and 60d/mL |
| Flow Rate Range | 1.0 ~ 999.9 mL/h |
| Increment | 0.1mL/h |
| Volume Limit | 1 ~ 9999 mL |
| Flow Rate Accuracy | = ± 5% (after calibration) |
| Purge Rate | 600 mL/h |
| KVO Rate | 1 mL/h |
| Occlusion Pressure | Pressure detection device with 8 sensitivities setting, 40 ~ 140KPa. |
| Air-in-line Detection | Air-in-line detection device with 8 sensitivities setting, 50 ~ 1000µL. |
| IV Set Management & Flow Rate Calibration | Up to 10 adjustment values for various brands IV set could be stored to make the operation more convenient. |
| Alarms | Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low Battery, Device failures, Three levels of alarm volume Low, Medium or High. |
| Display | Color LCD with high brightness |
| Power Source | AC: 100V ~ 240V, 50Hz/60Hz, = 25VA |
| Battery | Rechargeable Ni-MH battery: DC12V, 2000mAh, life: = 4 hours at 25mL/h |
| Classification | Class ?, CF, IPX4 |
| Dimensions and N.W. | 150mm x 150mm x 235mm; 1.8kg |
To contact Utech Medical Device Pty Ltd about UTMD Veterinary Infusion Pumps - IP300V use Get a quote.
Standard Package
Technical Specification:
| Fit IV Tubes | Can be used with any brand IV set after exactly calibration |
| Infusion Mode | Volumetric |
| Pumping Mechanism | Peristaltic finger pump |
| IV Sets | Standard IV sets of 10, 15, 20 and 60d/mL |
| Flow Rate Range | 1.0 ~ 999.9 mL/h |
| Increment | 0.1mL/h |
| Volume Limit | 1 ~ 9999 mL |
| Flow Rate Accuracy | = ± 5% (after calibration) |
| Purge Rate | 600 mL/h |
| KVO Rate | 1 mL/h |
| Occlusion Pressure | Pressure detection device with 8 sensitivities setting, 40 ~ 140KPa. |
| Air-in-line Detection | Air-in-line detection device with 8 sensitivities setting, 50 ~ 1000µL. |
| IV Set Management & Flow Rate Calibration | Up to 10 adjustment values for various brands IV set could be stored to make the operation more convenient. |
| Alarms | Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low Battery, Device failures, Three levels of alarm volume Low, Medium or High. |
| Display | Color LCD with high brightness |
| Power Source | AC: 100V ~ 240V, 50Hz/60Hz, = 25VA |
| Battery | Rechargeable Ni-MH battery: DC12V, 2000mAh, life: = 4 hours at 25mL/h |
| Classification | Class ?, CF, IPX4 |
| Dimensions and N.W. | 150mm x 150mm x 235mm; 1.8kg |