COSMED Fitmate PRO | Desktop Metabolic ...
Fitmate desktop metabolic systems introduce a new approach for the measurement of oxygen consumption at rest and during exercise in both clinical and health & fitness settings. Each Fitmate desktop device is equipped with a rechargeable battery, a large LCD screen and a built-in printer that allows testing without a computer or main power lead. All Fitmate systems manage test results and store information inside its internal memory, ready for upload to PC software (included).
KEY FEATURES
Complete product line. The Fitmate product line is designed to fit the needs of different users for specific applications and environments (clinical, research, performance, health & fitness).
Simplified approach to metabolic testing. The Fitmate measures oxygen uptake (at rest or during exercise) with the same accuracy of conventional systems with both O2 and CO2 sensors, but provides an easier test process (no calibration with gas cylinders, no warm-up).
Standalone use. The compact desktop design of the Fitmate offers an internal rechargeable battery, a large LCD screen and built-in thermal printer that allows testing without the need of a computer or main power lead.
Independently validated. The Fitmate has been validated for measuring REE (both with face mask and canopy) and VO2max (both real VO2max and prediction of maximal oxygen consumption with a sub-maximal protocol)
Accurate and reliable O2 sensor. The intrinsically linear electrochemical GFC sensor of the Fitmate has a 12-18 months lifespan and is user-replaceable.
Fitmate software. The Fitmate software suite provides the ability to manage data (save, archive, trending) measured with the Fitmate unit, plus a wider range of additional features such as energy balance, diet plan, ACSM exercise prescription, etc.
Integration with external devices. The Fitmate can be connected with third party devices for increased functionality including activity monitors (all Fitmate), pulse oximeters (Fitmate MED only), and stress ECGs (Fitmate MED only)
VERSIONS
Fitmate PRO
A new approach to simplified metabolic assessment during exercise and at rest
Fitmade MED
The first compact metabolic system for assessing functional capacity and risk stratification
Fitmate GS
The world’s only portable desktop indirect calorimeter for clinical testing and research
Fitmate
Complete desktop solution for accurate, quick & simple indirect calorimetry
TECH SPECS
HARDWARE | |
---|---|
O2 gas analyser | GFC |
Flowmeter - Exercise | Bidirectional turbine 0-28mm |
Flowmeter - Rest | Bidirectional turbine 0-18mm |
Display | Colour LCD 320 x 240 pixel |
Printer | High speed thermal printer |
Battery | Rechargeable Li-ion |
Internal Memory | Yes |
Interface ports | USB A-B, RS-232, HR-TTL, Flowmeter |
Electrical requirements | 100-240V ± 10% 50/60 Hz |
SOFTWARE | |
Software Interface | Fitmate |
OS Compatibility | Windows XP, VISTA, 7, 8, 10 |
Available languages (Software) | Italian, English, Spanish, French, German, Portuguese, Greek, Dutch, Chinese, Finnish, Russian, Slovenian |
Available languages (Firmware) | Italian, English, Spanish, French, German, Portuguese, Greek, Dutch, Turkish, Chinese, Korean, Japanese, Finnish, Polish, Russian, Slovenian |
To contact COSMED about COSMED Fitmate PRO | Desktop Metabolic System use Get a quote.
Fitmate desktop metabolic systems introduce a new approach for the measurement of oxygen consumption at rest and during exercise in both clinical and health & fitness settings. Each Fitmate desktop device is equipped with a rechargeable battery, a large LCD screen and a built-in printer that allows testing without a computer or main power lead. All Fitmate systems manage test results and store information inside its internal memory, ready for upload to PC software (included).
KEY FEATURES
Complete product line. The Fitmate product line is designed to fit the needs of different users for specific applications and environments (clinical, research, performance, health & fitness).
Simplified approach to metabolic testing. The Fitmate measures oxygen uptake (at rest or during exercise) with the same accuracy of conventional systems with both O2 and CO2 sensors, but provides an easier test process (no calibration with gas cylinders, no warm-up).
Standalone use. The compact desktop design of the Fitmate offers an internal rechargeable battery, a large LCD screen and built-in thermal printer that allows testing without the need of a computer or main power lead.
Independently validated. The Fitmate has been validated for measuring REE (both with face mask and canopy) and VO2max (both real VO2max and prediction of maximal oxygen consumption with a sub-maximal protocol)
Accurate and reliable O2 sensor. The intrinsically linear electrochemical GFC sensor of the Fitmate has a 12-18 months lifespan and is user-replaceable.
Fitmate software. The Fitmate software suite provides the ability to manage data (save, archive, trending) measured with the Fitmate unit, plus a wider range of additional features such as energy balance, diet plan, ACSM exercise prescription, etc.
Integration with external devices. The Fitmate can be connected with third party devices for increased functionality including activity monitors (all Fitmate), pulse oximeters (Fitmate MED only), and stress ECGs (Fitmate MED only)
VERSIONS
Fitmate PRO
A new approach to simplified metabolic assessment during exercise and at rest
Fitmade MED
The first compact metabolic system for assessing functional capacity and risk stratification
Fitmate GS
The world’s only portable desktop indirect calorimeter for clinical testing and research
Fitmate
Complete desktop solution for accurate, quick & simple indirect calorimetry
TECH SPECS
HARDWARE | |
---|---|
O2 gas analyser | GFC |
Flowmeter - Exercise | Bidirectional turbine 0-28mm |
Flowmeter - Rest | Bidirectional turbine 0-18mm |
Display | Colour LCD 320 x 240 pixel |
Printer | High speed thermal printer |
Battery | Rechargeable Li-ion |
Internal Memory | Yes |
Interface ports | USB A-B, RS-232, HR-TTL, Flowmeter |
Electrical requirements | 100-240V ± 10% 50/60 Hz |
SOFTWARE | |
Software Interface | Fitmate |
OS Compatibility | Windows XP, VISTA, 7, 8, 10 |
Available languages (Software) | Italian, English, Spanish, French, German, Portuguese, Greek, Dutch, Chinese, Finnish, Russian, Slovenian |
Available languages (Firmware) | Italian, English, Spanish, French, German, Portuguese, Greek, Dutch, Turkish, Chinese, Korean, Japanese, Finnish, Polish, Russian, Slovenian |
To contact COSMED about COSMED Fitmate PRO | Desktop Metabolic System use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product