Quanta System Accure 1723nm Laser for ...
1- ACCURE Laser use Fiber laser source 1726 nm
Fiber Laser generates extremely stable 1726nm wavelengths +- 1nm deviation, meaning maximum efficacy and all-time performance on peak absorption on the Sebaceous glands curve. Clinical trials show max deviation tolerance should be within +-3nm of 1726 to achieve good results with min thermal damage due to water energy absorption. Diode lasers which can fluctuate up to +-10nm, resulting in poorer Acne treatment.
2- Integrated 4 Thermal Cameras for precise continuous skin temperature monitoring
Every skin is different from one patient to another, treatment depends on skin moisture levels, and this influences the energy required for each treatment. ACCURE Laser performs skin monitoring and auto-control energy delivery as the key to achieving maximum efficiency and long-lasting results.
3- Advanced Optical Scanner and Large Spot Size
Even laser distribution, large 6mm x 6mm square spot size scanner and 1.7mm penetration to effectively attack the sebaceous glands.
4- Integrated Air-Cooling System to minimize thermal injury risk during laser therapy
ACCURE Laser uses built-in Air-cooling system can reach -15°c, reducing pain level. Many patients reported a level of pain 5/10 or less. With ACCURE, we do not use water coolant on skin and we do not risk skin thermal injury.
5- Fully automated operation, setting target temperature is the only adjustment
Set temperature for face to 43°c, forehead to 41°c, and back body to 45°c, and the ACCURE Laser does all the calculations and delivers the treatment. No further involvement is required by the Operator.
6- ACCURE Laser completes 6 automated passes for each treatment area
Each pass delivers increased energy and temperature whilst the integrated thermal cameras continuously monitor until target is achieved. The first 5 passes are performed UNDER the pain level, with the last pass boosted to achieve temperature target. Treatment remains more comfortable for the patient.
7- We mark the treatment area to ensure 100% treatment coverage
We ensure there is no missing areas.
8- Integrated AI Software, Fully Automated OR Manual mode of operation with integrated safety monitoring.
9- Recommend 4 treatments, one month apart.
10- No chipcard, min treatment consumables.
To contact Aussie Medi Tech about Quanta System Accure 1723nm Laser for Effective Acne Treatment use Get a quote.
1- ACCURE Laser use Fiber laser source 1726 nm
Fiber Laser generates extremely stable 1726nm wavelengths +- 1nm deviation, meaning maximum efficacy and all-time performance on peak absorption on the Sebaceous glands curve. Clinical trials show max deviation tolerance should be within +-3nm of 1726 to achieve good results with min thermal damage due to water energy absorption. Diode lasers which can fluctuate up to +-10nm, resulting in poorer Acne treatment.
2- Integrated 4 Thermal Cameras for precise continuous skin temperature monitoring
Every skin is different from one patient to another, treatment depends on skin moisture levels, and this influences the energy required for each treatment. ACCURE Laser performs skin monitoring and auto-control energy delivery as the key to achieving maximum efficiency and long-lasting results.
3- Advanced Optical Scanner and Large Spot Size
Even laser distribution, large 6mm x 6mm square spot size scanner and 1.7mm penetration to effectively attack the sebaceous glands.
4- Integrated Air-Cooling System to minimize thermal injury risk during laser therapy
ACCURE Laser uses built-in Air-cooling system can reach -15°c, reducing pain level. Many patients reported a level of pain 5/10 or less. With ACCURE, we do not use water coolant on skin and we do not risk skin thermal injury.
5- Fully automated operation, setting target temperature is the only adjustment
Set temperature for face to 43°c, forehead to 41°c, and back body to 45°c, and the ACCURE Laser does all the calculations and delivers the treatment. No further involvement is required by the Operator.
6- ACCURE Laser completes 6 automated passes for each treatment area
Each pass delivers increased energy and temperature whilst the integrated thermal cameras continuously monitor until target is achieved. The first 5 passes are performed UNDER the pain level, with the last pass boosted to achieve temperature target. Treatment remains more comfortable for the patient.
7- We mark the treatment area to ensure 100% treatment coverage
We ensure there is no missing areas.
8- Integrated AI Software, Fully Automated OR Manual mode of operation with integrated safety monitoring.
9- Recommend 4 treatments, one month apart.
10- No chipcard, min treatment consumables.